2024 Pentair intelliflo display not working - Pool control at the touch of a wrinkly finger. Smart phone control, voice control, smart watch control…it’s smart pool control. Wherever, whenever and however you want. Whether you’re installing a pool, or reconstructing one, Pentair has the latest technology to keep you in touch with your pool’s every function and feature. From anywhere.

 
The innovative new design of the IntelliFlo Variable Speed pump will replace all other pumps. This is done by utilizing 8 variable speeds that can help cut the pool portion of utility bills up to 90% and save you hundreds of dollars per year and thousands of dollars over its life span. The Pentair 011018 pump works on any pool or spa .... Pentair intelliflo display not working

Jun 15, 2018 · Potomac. Jun 14, 2018. #1. I replaced my old pump with the Pentair 342001 Superflo VS today. When I first powered it up, the screen came on no problem. I primed the pump, then turned it on for the first time. The pump started up, got almost to full running, then shut off. Now all it will do is blink the LEDs. I have turned off the breaker, then ... About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ...May 16, 2018 · So now the pump is running with the correct constant power. The problem I am having is with the RPM settings, and the schedule. Problem 1: I have setup 4 speeds for the Intelliflo directly on the easytouch panel, it will only allow me to program 4. There is an RPM setting for POOL, another for SPA, another for "EITHER HEATER" and one for "CLEANER." The Pentair Home app accepts a wide range of Pentair Connected water devices that can be used throughout a home to help your customers move, improve and enjoy their water. However, at this time, Pentair Home and Pentair Pro are not integrated with other smart home devices, or connected via voice with at home assistants like Alexa or Google Home.it appears to be a pentair check valve, if you wanted to not have spa spillover running constant and therefore be able to run the vsf pump at a lower speed, you could pickup a pentair 2 way and swap the "guts" to disable the constant spillover. Then program spillway in screenlogic for a couple times a day.Aug 27, 2022 · The light icon should turn green. Then go out and look at the actual light and confirm it is on. If it is on, turn the light off using the light button on the EasyTouch. Then confirm that the ScreenLogic light icon goes off. If this works, it proves that your RS-485 com port is working. Jul 7, 2014. 31,557. Bedford, TX. Nov 13, 2022. #2. jv, It certainly could be that your control head has some water damage, but the very first thing to check is to make sure the pump is getting 240 Volts AC right where it comes into the pump. The pump should be getting constant AC power, so even if the LCD is damaged, you should see some lights.The SolarTouch Solar Control System offers full digital control for the most precise, efficient, swimming pool heating possible. The digital thermostat is set with the touch of a button and will monitor the temperature of the pool water and solar collectors. SolarTouch Control System integrates with IntelliFlo and IntelliPro Variable Speed pumps for unparalleled efficiency. 516 satisfied customers Lost power and now the Pentair Intelliflo VSF is in alarm Lost power and now the Pentair Intelliflo VSF is in alarm mode and won't run. All the keys are locked out bc I use a control panel so I can't figure out … read more CertifiedPoolPro Owner/Operator Pool Servi... Bachelor's of Science 637 satisfied customersJun 5, 2022 · Hi My pentair intelliflo pump won't turn on. No power. Screen is blank. Contractor's Assistant: I'll do all I can to help. How long have you been dealing with this? Today. I was opening my pool. Contractor's Assistant: Do you plan on doing the work yourself? Yes. Contractor's Assistant: Is there anything else the Pool Technician should know ... Jun 3, 2018 · The pump is just a little over 1 year old so past the warranty. It was installed by a professional pool company. The Pentair Intelliflo 2 VST 1.5 HP pump had been working great then abruptly just stopped after a scheduled program. There is no display at all, there were no warning alarms before it quit working either. 13 years ago. reset VF to factory=. Press and hold 4 top buttons then release. Then hold down the two middle keys while holding down select and escape at the same time. At Application set up press select. To govern the pump to a 2HP or 1HP max, press the 4 top keys, arrow to PAR 699, change to 1 or 2 and power down, power up.I went out today to look at the clean cycle time settings and found the pump "locked" with "Display not Active!" on the LED screen. No buttons work, not any. I have to power off by flipping the breaker, waiting at least one minute, and I get the pump menus back. However, once running for any length of time the system locks back up.A Pump That Knows Your Pool’s Flow. A pool that is crystal clear and inviting is key to the perfect backyard oasis. The IntelliFlo3 VSF Pool Pump leverages built-in sensorless flow control for optimum water flow adjusts to pool conditions, keeping your pool performing at its best. Set up, monitor and operate the pump from anywhere with ... Aug 14, 2016. 9. Austin. Jun 28, 2017. #5. Great news! The Pentair Keypad Assembly Kit 357527Z arrived today from SunPlay. It wasn't "plug-and-play" by any means but the keypad and the female connector work properly with my Intelliflo 011018 pump. That saved me more than $330 versus buying an entire drive off Ebay.Pentair 357527Z Swimming-Pool-Pump-Accessories, White. Visit the Pentair Store. 4.0 106 ratings. 50+ bought in past month. -35% $28794. List Price: $439.99. Part Number: 357527Z. Innovative and high-performance parts. Kit Keypad Top Cvr Asy Intelliflo Almd.If you have questions about ordering Pentair replacement parts, and pool products, please use the following contact information: CUSTOMER SERVICE / TECHNICAL SUPPORT Customer Service (8 A.M. to 4:30 P.M. — Eastern and Pacific Times) Phone: (800) 831-7133 Fax: (800) 284-4151 Web site Visit www.pentair.com for more information about Pentair ...Apr 29, 2020 · About. Pentair Pool Quick Link for Parts/Equipment: https://amzn.to/3q6MXmf Ask your Questions or search from our database of answers: https://askthepoolguy.com/que... 0:00 / 13:12 Off Menu: Pentair Intelliflo Pool Pump LCD Screen Repair | see description Retro Recipes 175K subscribers 588 39K views 5 years ago Occasionally we go 'off menu' & look at things a...#1 Similar threads found, but want to make sure I didn't miss an easier fix. My pump display went dead and the breaker was tripped. Reset the breaker and it …Aug 20, 2021 · Aug 20, 2021. #1. So I understand that my 6 year old Pentair Intelliflo VS clock forgets time of day at power loss and the Pentair solution is to spend $800 for a new drive kit 356879Z. Really disappointing that Pentair hasn't figured out a way to make the power backup for the clock replaceable. No one should have to spend $800 to replace a ... Plano, TX. May 4, 2017. #37. Have to say I was fairly skeptical on this fix (my LCD screen on Pentair has been blank for a couple of years) but opted to try it as described in this thread. Pics and details from Rwhite692 were very helpful. Spent $4 for foam weatherstrips at HD and that was pretty much it.Pentair Pool Pump Display Not Working . Pentair pool pumps are a common type of pool pump used in many pools. If you have a Pentair pool pump, it is important to know that the display on the front of the pump may not always work. This can be due to several reasons, such as a power outage or a problem with the wiring.The Pentair is feed through a a seimens 40 amp breaker. It looks like is 240v going to the pump. I'm new to all this so I sure I don't have it all correct. I followed the wires from the breaker to check for power on far left terminal and where the wire from the breaker is feed to the line in has power. The load out wire doesn't have power.Now, the nickname screen will display and you will enter the name you would like your pump to by within the Pentair Home app and press save. Finally, the installation completed screen will appear, and press continue. ... Pentair IntelliFlo 3HP Pump Comparison 011056 vs 011076. Pentair IntelliFlo3 VSF 3.0HP with I/O Board 011076 - …A Pump That Knows Your Pool’s Flow. A pool that is crystal clear and inviting is key to the perfect backyard oasis. The IntelliFlo3 VSF Pool Pump leverages built-in sensorless flow control for optimum water flow adjusts to pool conditions, keeping your pool performing at its best. Set up, monitor and operate the pump from anywhere with ......more Troubleshooting a Pool Pump Motor Pentair Intelliflo Variable Speed pumps are great pumps, but occasionally parts fail and they need to be fixed.I get service calls from …http://www.pentairpool.comhttp://www.poolfyi.comhttp://www.facebook.com/pages/Pentair-Aquatic-Systems/295848388965http://twitter.com/pentairpoolAug 4, 2022 · Intelliflo VS pump is supposed to have constant power and not wired through the filter pump relay. The Intelliflo VS pump should be controlled by the RS-485 comm line. What does the Intelliflo display show? If the pump can be controlled by its control panel then the RS-485 comm control to the pump is not active. Still have questions on your Pentair IntelliFlo? Our customer service team is here to help you.Call: 1.800.831.7133. Find the support you need to connect your water devices to the Pentair Home and Pentair Pro apps. Pentair has FAQs and documentation to get you started. Jun 3, 2018 · The pump is just a little over 1 year old so past the warranty. It was installed by a professional pool company. The Pentair Intelliflo 2 VST 1.5 HP pump had been working great then abruptly just stopped after a scheduled program. There is no display at all, there were no warning alarms before it quit working either. This video outlines basic programing for Pentair Intelliflo, Intelliflo 2 VST, Intellipro, IntellifloSVRS+VS, and Intelliflo XF pumps. We'll get into flow ra...Are you struggling with a laptop that suddenly displays a black screen? This common issue can be frustrating and disruptive, especially if you rely on your laptop for work or personal use.Salt Cell Troubleshooting with Pentair on the intellichlor ic20 or ic40. July 18, 2016 Ask the Pool Guy. We just had some salt cells requiring maintenance. Pentair has owners manuals and troubleshooting guides on their website, here are a couple for quick reference! Ask the Pool Girl, Ask the Pool Guy, Case Studies, Products, Service Guides ...Show Less. Ask Your Own Pool and Spa Question ... If there is a service mode check to see if all works in that setting.Powering down the entire system for ten minutes is always the first/best way to initially tested whether there is an actual issue or just a momentary glitch that shut down the system, ... I have a Pentair intelliflo pro and a ...Currently, I have the following issues: 1. EasyTouch will not operate the Intelliflo. Pump display shows "Display not active" indicating good comms. Pump work fine on schedule programmed at the unit itself. 2. EashTouch operates all other features, including the iChlor connected to the same J20. 3.Double check the speed settings for your intelliflo on your easytouch. Go to settings > intelliflo > pump #1 > speeds. Check your pool speed. Just had a customer last week with the same issue and his pool speed was set to 400 rpms. At this low of a speed it looked like the pump was off. Also check the pumps communication to the panel.A pool that is crystal clear and inviting is key to the perfect backyard oasis. The IntelliFlo3® VSF Pool Pump leverages built-in sensorless flow control for optimum water flow and adjusts to pool conditions, keeping pools performing at their best. Set up, monitor and operate the pump from anywhere with wireless technology control through the ...Drive Assembly Removal and Installation To remove the IntelliFlo ® VF Variable Flow Pump drive and control panel from the motor assembly: 1. Make sure all electrical breakers and switches are turned off before removing the drive. 2. Disconnect the communication cable from the IntelliFlo pump.Be sure that you have power gong to pump first by checking wires with a volt meter. If the wires have power and they are properly attached to pump motor, and there is no display on the intelliflo screen then it is a bad drive. Call pentair with your invoice and serial number. Follow the number above prompts and they will get you a new pump.INTELLIFLO ® O i ti i i P/N 356916 Rev. A 4/27/16 If you have questions about ordering Pentair Aquatic Systems replacement parts, and pool products, please contact: CUSTOMER SERVICE / TECHNICAL SUPPORT Customer Service and Technical Support, USA (8 A.M. to 4:30 P.M. — Eastern/Pacific Times) Phone: (800) 831-7133 Fax: (800) 284-4151 Web siteThe pentair intelliflo vsf display is not active when there's a problem with the wiring, power, or the display module itself. Troubleshooting these issues can help fix the problem and get the display working again. The pentair intelliflo vsf pump is a highly efficient pool pump that can help save on electricity costs.TampaPoolNovice. Hi. I’m hoping someone can help me here. I have a Pentair superflo VS variable speed pump only a few years old. I can see water drops inside my LCD screen. The pump will turn on and the green light shows but the pump isn’t running. The green light still goes to each 1,2,and 3 setting so it’s following its program.Connecting an IntelliFlo Filter Pump to the LOAD SIDE terminals of the Filter Pump Relay is NOT correct and seems to be a common mistake made by installers who are not familiar with the IntelliFlo line of pumps and/or Pentair Automation Systems. Notice that the IntelliChlor is connected to the two LOAD SIDE terminal screws.Press the Start/Stop button on the drive keypad. If. the pump is currently scheduled to run it will start. Note: If the pump is not schedule to start, press a. Speed button to begin a manual override that will. start the pump. Check if the pump can be rotated by hand and. remove any blockage.The innovative new design of the IntelliFlo Variable Speed pump will replace all other pumps. This is done by utilizing 8 variable speeds that can help cut the pool portion of utility bills up to 90% and save you hundreds of dollars per year and thousands of dollars over its life span. The Pentair 011018 pump works on any pool or spa ...Slide projectors work by shining light through specialized photographs called slides. When the light goes through the slide, it enlarges the photograph and displays the image on a screen or on the wall. Usually, slide projectors use a carou...Jan 6, 2017 · The Pentair is feed through a a seimens 40 amp breaker. It looks like is 240v going to the pump. I'm new to all this so I sure I don't have it all correct. I followed the wires from the breaker to check for power on far left terminal and where the wire from the breaker is feed to the line in has power. The load out wire doesn't have power. Intelliflo VSF Troubleshooting - Design Pool & SpaPotomac. Jun 14, 2018. #1. I replaced my old pump with the Pentair 342001 Superflo VS today. When I first powered it up, the screen came on no problem. I primed the pump, then turned it on for the first time. The pump started up, got almost to full running, then shut off. Now all it will do is blink the LEDs. I have turned off the breaker, then ...May 4, 2023 · Intelliflo VS does not start turning but powers on via intellicenter easytouch2 4 firmware 2.140. I had an issue with my pump that had been working for years. It lost communications. I had a spare cable and changed it and reset the pump and get the display not active like i should but the... (*) Note: Older IntelliFlo/IntelliPro 4x160/VS-3050 pumps do not have a control panel display) and do not display “Ext Ctrl.” The SolarTouch controller can cool the pool/spa by circulating water through the solar panels when the solar collectors are at a lower temperature than the pool/spa water (typically at night).Currently, I have the following issues: 1. EasyTouch will not operate the Intelliflo. Pump display shows "Display not active" indicating good comms. Pump work fine on schedule programmed at the unit itself. 2. EashTouch operates all other features, including the iChlor connected to the same J20. 3.Pentair Intelliflo Display Not Working Identifying Pentair Intelliflo Display Problems. Taking care of a pool precisely and efficiently is super important. Potential Causes of Pentair Intelliflo Display Not Working. Display issues can stem from a variety of sources, each of... DIY Troubleshooting ...0:00 / 1:22 Pentair intelliflo pump: Display not active askthepoolguy 11.6K subscribers Subscribe Like Share Save 24K views 3 years ago #teamlegendary #legendaryescapes #askthepoolguyJul 8, 2019 · I have had my Pentair intelliflo VS pump just over 2 years now. I just noticed that the LCD screen is blank. it does not show anything. the pump works fine however. I cannot program anything since i can't see what it is i am programming. i check out to replace the screen i need to... www.troublefreepool.com. Also, this youtube video that seem ... 16. Jan 17, 2011. #1. Tried to operate in service mode yesterday, but pump would not operate. Reset button on Intellitouch control panel panel then started flashing. Reset the button, but still the pump will not function. Interior IS4 control panel operates with no problem when in Auto mode. The same night, used the spa and noticed the spa ...Jun 7, 2020 · I have a Pentair Variable Speed Intelliflo pump that suddenly stop working. I tried to start the pump through the Pentair Easy Touch control panel as well as with the SpaSide buttons with no luck. Finally I switch the Easy Touch panel to Service mode so that I could start the pump directly from the pump itself. Still no luck. Positive ethics can have a beneficial impact both personally and professionally. Employees who display good ethics in the workplace will earn a stellar reputation that often helps with career advancement.First, check the water level in your skimmer. If it’s less than half way up the skimmer, that could be where the air is going. Also, check the basket lid o-ring to make sure it’s getting a good seal. It’s good to go ahead and put some silicon pool lube on the o-ring and put it back in just to ensure that seal.Re: Pentair Intelliflo Variable Speed LCD Not Working. Postby Teapot » Thu 02 Aug, 2018 23:36. An issue for your pool services insurers to wonder over. Otherwise send it for a service. Pentair products are weak theses days, valves and handles break, pumps and controllers not water resistant. I choose other manufacturers if possible.Oct 25, 2017 · The IntelliFlo is controlled by a serial cable that gets plugged into the pump's control panel. When the cable is attached and the EasyTouch is in the Auto mode (Not Service mode) the pump's display will read "Display Not Active". If the pump's display does not say Display Not Active, then that is a pretty good indication that the communication ... Troubleshooting a Pool Pump Motor Pentair Intelliflo Variable Speed pumps are great pumps, but occasionally parts fail and they need to be fixed.I get service calls from customers complaining...Understanding The Pentair Intelliflo Display Issue. Having trouble with your pentair intelliflo display? Discover solutions to the pentair intelliflo display issue and get your display working properly in no time. If you're facing issues with your pentair intelliflo display, it can be frustrating and inconvenient.Autumn leaves put on a beautiful display when they’re on the trees, but once the leaves fall they create an unsightly mess. A leaf blower makes quick work of clearing a yard or patio area of the fall leaves, but it’s useful for far more tha...I am assuming you have an Intelliflo. With the IntelliTouch in "Auto" the display should read "Display not active". ... The com bus is not working as the pump never says display not active. That is always my first check... Reply. Report. Jimrahbe. Mod Squad. ... Pentair MasterTemp not responding to ScreenLogic. Chas717; Jun 18, 2023; …Ground and two hot leads.. The hot leads are called L1 and L2. Does not really matter which is which. Measure between L1 and L2 and not L1 to ground and then L2 to ground. What I would do is start with the pump off. Measure L1 to L2 and confirm that you have about 240 volts. If you do not have about 240 volts, there is no sense going any …Plano, TX. May 4, 2017. #37. Have to say I was fairly skeptical on this fix (my LCD screen on Pentair has been blank for a couple of years) but opted to try it as described in this thread. Pics and details from Rwhite692 were very helpful. Spent $4 for foam weatherstrips at HD and that was pretty much it.Hi My pentair intelliflo pump won't turn on. No power. Screen is blank. Contractor's Assistant: I'll do all I can to help. How long have you been dealing with this? Today. I was opening my pool. Contractor's Assistant: Do you plan on doing the work yourself? Yes. Contractor's Assistant: Is there anything else the Pool Technician should know ...Step by step on how to get your Pentair Intelliflo Pump to be controlled from your Easy Touch PanelPentair INTELLIFLO 2 VST Installation And User Manual (36 pages) VARIABLE SPEED PUMP. Brand: Pentair | Category: Water Pump | Size: 3.72 MB. Table of Contents. Table of Contents. 2. Important Pump Warning and Safety Instructions. 3. Pump Overview.The IntelliFlo displays all alarms and warnings on the control panel display. When an alarm or warning condition. exists, the corresponding LED will be lit on the display. All control panel buttons are disabled until the alarm or. warning is acknowledged with the Enter button. Press the Reset button to clear the alarm once the fault.I have the ScreenLogic Config app on my iPhone. I went to the IntelliFlo Setup section and see Pump 1 and Pump 2 listed. Pump 1 is my main pump and Pump 2 is my cleaner pump. Both pumps are set to "none," which makes sense since neither was a IntelliFlo. Now that Pump 1 is an IntelliFlo, I know it's obvious that I should set it to VSF.Adapt code to send from SRC 0x10 instead of 0x21 (33) (PR Zuntara patch 1 #2) Test with the newly modified code that the pump responds to commands. Check that the pump is in active time schedule and start led is on + external programs are configured. 0x0f: is the broadcast address, it is used by the more sophisticated controllers as in their ...Nov 13, 2022 · Jul 7, 2014. 31,557. Bedford, TX. Nov 13, 2022. #2. jv, It certainly could be that your control head has some water damage, but the very first thing to check is to make sure the pump is getting 240 Volts AC right where it comes into the pump. The pump should be getting constant AC power, so even if the LCD is damaged, you should see some lights. It will either say, "Display not Active" or it will show the manual operation display.. If the panel is blank, then either the pump/drive is bad, or you do not have any power going to the pump.. The IntelliFlo gets constant AC power from a circuit breaker inside your EasyTouch..2.0 or higher. • Instructions on how to factory reset a Pentair IntelliFlo pump. ... If these instructions do not work, refer to the Pentair pump's manual for ...Pentair IntelliFlo VSF is the first pump to combine true set it and forget it flow technology paired with the smart connectivity of Pentair's app. This pump sets a new bar for performance with built-in sensorless flow control for effortless optimum flow and aids in keeping the pool crystal clear and inviting, no matter what it requires. Pentair's …May 18, 2023 · Yes the RS-485 cable.. A single speed pump is controlled by an Aux relay and does not use the RS-485 com port. A VS pump is controlled by the RS-485 cable and is not wired to any Aux relay. It sometimes takes a minute or two for the "Display not Active" screen to go away when you first go into the Service mode. Pentair intelliflo display not working

Re: Intelliflo Pump has No Info on LED Screen. I have to wait on the circuit board waterproofer stuff before I do it. It is on order from Amazon. If I am pulling it out to work on it I want to do it right. IOW I am doing the weatherstripping and circuit board protection. I will turn the screen 180° as well because when my heater goes in I wont .... Pentair intelliflo display not working

pentair intelliflo display not working

Swimables 2" Hi-Temp Union Compatible with All Pentair Whisperflo and Intelliflo Pumps for Inground Swimming Pool 21063-200-000-2" MIP x 2" Slip PVC - Made in USA - 2 Pack. ... the display screen stopped working on July 16th, I bought this new screen on July 17th & it’s now Aug 22nd ( literally 35 days after) it’s already stopped working. ...Aug 29, 2015 · Press the Start/Stop button on the drive keypad. If. the pump is currently scheduled to run it will start. Note: If the pump is not schedule to start, press a. Speed button to begin a manual override that will. start the pump. Check if the pump can be rotated by hand and. remove any blockage. Posts: 10 Joined: Fri 23 Feb, 2018 18:21 How to fix Pentair Intelliflo bad LCD Postby Perifractic » Fri 23 Feb, 2018 18:31 Hi guys, I'm a proud pool owner and recently ran into a problem with my Pentair intelliflo pump. The LCD had gone blank or just showed a few lines.My display is blank, buttons don't work, and the backlight is on. The pump runs the schedule even with the display disconnected but for some reason the "quick clean" led is on. ... Pentair Intelliflo pump - stopped working, no activity at LCD. richard.chen.610; Sep 24, 2023; Pumps, Filters, and Plumbing; Replies 8 Views 140. Pumps, Filters, and ...I have Pentair Intelliflo VSF pump with a 33000 gallon pool. ... Correct, When the service mode is on, I can change the settings at the actual pump. When the Auto mode is on, it says Display not Active. I understand this. ... The only way to really have my family member getting his pool working a predictable way is for me to understand how …0:00 / 13:12 Off Menu: Pentair Intelliflo Pool Pump LCD Screen Repair | see description Retro Recipes 175K subscribers 588 39K views 5 years ago Occasionally we go 'off menu' & look at things a...Get instant status information and remotely monitor all your connected Pentair pool products, anytime from anywhere. ... I had no problems with getting all my ...• Instructions on how to factory reset a Pentair IntelliFlo pump. These instruction may not work for all IntelliFlo Models. If these instructions do not work, refer to the Pentair pump’s manual for complete instructions on how to perform a factory reset. 1. If already connected to the Pump Converter Board, disconnect the black comm wire IntelliConnect. IntelliConnect is an entry level automation system for simple pools. IntelliConnect can control Pentair IntelliFlo VS pumps, a Intellichlor or iChlor SWG, up to 5 pool devices, operates almost any 2 on/off items through two 20-Amp, 2 HP relays, and works through an app for smart devices.Apr 29, 2020 · About. Pentair Pool Quick Link for Parts/Equipment: https://amzn.to/3q6MXmf Ask your Questions or search from our database of answers: https://askthepoolguy.com/que... Livermore/Ca. Apr 4, 2015. #1. I have a pentair easy touch control panel p/n 520474 Rev d. I also have an intelliclor inline clorinator. I unplugged the chlorinator and when I plugged it back in the display on my easy touch panel went out. Also none of the buttons on the panel work now either. If I turn the circuit breaker off and on the ...I have Pentair Intelliflo VSF pump with a 33000 gallon pool. ... Correct, When the service mode is on, I can change the settings at the actual pump. When the Auto mode is on, it says Display not Active. I understand this. ... The only way to really have my family member getting his pool working a predictable way is for me to understand how …Basically the pump can see the EasyTouch but the EasyTouch can't see the pump.. The RS-485 has different circuits.. It sends commands out on one circuit and receives commands on another circuit. We have seen several pump where the send circuit is dead, but the pump's screen still says "Display not active" because the receive circuit is still ...Re: Intelliflo Pump has No Info on LED Screen. I have to wait on the circuit board waterproofer stuff before I do it. It is on order from Amazon. If I am pulling it out to work on it I want to do it right. IOW I am doing the weatherstripping and circuit board protection. I will turn the screen 180° as well because when my heater goes in I wont ...I would purchase the newer model that has the rotatable display. There are also flow control models that allow you to set a flow rate set-point. DO NOT GET THE SVRS (safety vacuum release system) MODEL. All IntelliFlo and WhisperFlo Pentair pumps use the same wet end design. So there should be no plumbing work necessary.A Six’s thermometer functions by using alcohol to expand or contract the mercury inside to display both the highest and lowest temperatures of a given time period. There are bulbs at the top of each arm of the tube, one above each indicator...0:00 / 1:22 Pentair intelliflo pump: Display not active askthepoolguy 11.6K subscribers Subscribe Like Share Save 24K views 3 years ago #teamlegendary #legendaryescapes #askthepoolguyConnecting an IntelliFlo Filter Pump to the LOAD SIDE terminals of the Filter Pump Relay is NOT correct and seems to be a common mistake made by installers who are not familiar with the IntelliFlo line of pumps and/or Pentair Automation Systems. Notice that the IntelliChlor is connected to the two LOAD SIDE terminal screws.Display issues can pop up in a few different ways: think flickering screens, touch controls that don't respond, or error messages that might look like gibberish if you're not familiar with them. When you encounter stuff like this, it's time to put on your detective hat and get troubleshooting.1. Replace the keypad (Cheapest and simplest solution but there is conflicting info if this can be done) 2. Replace the complete drive assembly (Expensive but may be most reliable solution) 3. Bypass keypad with external/remote control system (Expense on order of replacing drive assembly)May 5, 2019. #1. I have a 2015 Pentair Intelliflo VS variable speed pump 011018 in which water got inside the poorly designed display. The pump is still running but on the last programmed low speed only. The display is blank and I can't run or program the pump to any other higher speed. A fix would be to replace the drive 353251 for around $630.IntelliFlo® Variable Speed Programmable Pump Installation and User’s Guide. Table of Contents IntelliFlo® Variable Speed Pump Installation and User’s Guide i If you have questions about ordering Pentair Water Pool and Spa (“Pentair”) replacement parts, and pool products, please use the following contact information:Time Out: Pump is not running on preset schedule. This. CAN. BEFORE. Start/Stop ... Ensure that the pump display says. “DISPLAY NOT ACTIVE”. A defective device ...The pentair intelliflo vsf display is not active when there's a problem with the wiring, power, or the display module itself. Troubleshooting these issues can help fix the problem and get the display working again. The pentair intelliflo vsf pump is a highly efficient pool pump that can help save on electricity costs.The pentair intelliflo display not working may be due to a malfunction or faulty connection. If you are experiencing this issue, ensure that the display is properly …Aug 29, 2015 · Press the Start/Stop button on the drive keypad. If. the pump is currently scheduled to run it will start. Note: If the pump is not schedule to start, press a. Speed button to begin a manual override that will. start the pump. Check if the pump can be rotated by hand and. remove any blockage. Nov 13, 2022 · Jul 7, 2014. 31,557. Bedford, TX. Nov 13, 2022. #2. jv, It certainly could be that your control head has some water damage, but the very first thing to check is to make sure the pump is getting 240 Volts AC right where it comes into the pump. The pump should be getting constant AC power, so even if the LCD is damaged, you should see some lights. Jun 13, 2021. #1. I believe I just had TWO "2" of my 3HP Intelliflo VS Pump Drives go out at the same time during a heavy rain spell in Dallas last week. I have voltage at the terminals that connect into the pump, but nothing on the displays. See pics for model details. Sadly, one of these pumps is almost brand new and the other was rehabbed ...I have a Pentair Variable Speed Intelliflo pump that suddenly stop working. I tried to start the pump through the Pentair Easy Touch control panel as well as with the SpaSide buttons with no luck. Finally I switch the Easy Touch panel to Service mode so that I could start the pump directly from the pump itself. Still no luck.default speed (1500 RPM) except for IntelliFlo VF (Press Manual button on pump to set RPM and GPM speeds. See the IntelliFlo VF Pump Manual (P/N 350075). IntelliFlo pump installed (standalone mode): If an IntelliFlo pump is detected, it will go to stand-alone mode (may take up to two minutes). The pump is not being controlled by SolarTouchI went out today to look at the clean cycle time settings and found the pump "locked" with "Display not Active!" on the LED screen. No buttons work, not any. I have to power off by flipping the breaker, waiting at least one minute, and I get the pump menus back. However, once running for any length of time the system locks back up.The pump will continue to run, but it is not achieving the desired speed because it is running at the maximum flow rate. ... Ensure that the pump display says “ ...If you have any questions please contact us through our website at: https://www.poolspecialists.com/Jun 7, 2020 · I have a Pentair Variable Speed Intelliflo pump that suddenly stop working. I tried to start the pump through the Pentair Easy Touch control panel as well as with the SpaSide buttons with no luck. Finally I switch the Easy Touch panel to Service mode so that I could start the pump directly from the pump itself. Still no luck. (*) Note: Older IntelliFlo/IntelliPro 4x160/VS-3050 pumps do not have a control panel display) and do not display “Ext Ctrl.” The SolarTouch controller can cool the pool/spa by circulating water through the solar panels when the solar collectors are at a lower temperature than the pool/spa water (typically at night). How to fix Pentair Intelliflo bad LCD. Hi guys, I'm a proud pool owner and recently ran into a problem with my Pentair intelliflo pump. The LCD had gone blank or …1 Answer. Sometimes when a salt cell goes bad the lights all go out. If the unit is powered correctly it only receives power when the pump is running -and as long as it is plugged in it should be showing lights. A 2014 cell even shut down for 1 years would still have met it’s life expectancy. We’ve done the math for here in Michigan and a ...Step by step on how to get your Pentair Intelliflo Pump to be controlled from your Easy Touch Panel31,615. Bedford, TX. May 24, 2019. #5. mao, The control panel cannot be blank... It will either say, "Display not Active" or it will show the manual operation display.. If the panel is blank, then either the pump/drive is bad, or you do not have any power going to the pump.. The IntelliFlo gets constant AC power from a circuit breaker inside ...Salt Cell Troubleshooting with Pentair on the intellichlor ic20 or ic40. July 18, 2016 Ask the Pool Guy. We just had some salt cells requiring maintenance. Pentair has owners manuals and troubleshooting guides on their website, here are a couple for quick reference! Ask the Pool Girl, Ask the Pool Guy, Case Studies, Products, Service Guides ...Pool Pump not Turning On? It could be okay. Trust me on this. Don't toss that pool pump motor until you try this simple trick to see if you can get it going ...A VS pump is controlled by the RS-485 cable and is not wired to any Aux relay. It sometimes takes a minute or two for the "Display not Active" screen to go away when you first go into the Service mode. In theory, when the pump shows "Display not active" it means the RS-485 is working..I have the Intelliflo also. I run mine at 1100 rpm for skimming and making chlorine with the SWG. It uses 150 watts at 1100 rpm and works great. Here is how the math works 168 watts x 8 hours run = 1344 watts ÷1000 = 1.344 kWh x 30 days = 40.32 kWh x 10.25c/kWh = $4.13 per monthSome famous Filipino sculptors are Rey Paz Contreras, Eduardo Castrillo, Solomon Saprid and Napoleon Abueva. A work by Napoleon Abueva, titled “The Sculpture,” has been on display in the United Nations headquarters.May 5, 2019. #1. I have a 2015 Pentair Intelliflo VS variable speed pump 011018 in which water got inside the poorly designed display. The pump is still running but on the last programmed low speed only. The display is blank and I can't run or program the pump to any other higher speed. A fix would be to replace the drive 353251 for around $630.Nov 13, 2022 · Jul 7, 2014. 31,557. Bedford, TX. Nov 13, 2022. #2. jv, It certainly could be that your control head has some water damage, but the very first thing to check is to make sure the pump is getting 240 Volts AC right where it comes into the pump. The pump should be getting constant AC power, so even if the LCD is damaged, you should see some lights. H2O-PRO • 3 yr. ago. Double check the speed settings for your intelliflo on your easytouch. Go to settings > intelliflo > pump #1 > speeds. Check your pool speed. Just had a customer last week with the same issue and his pool speed was set to 400 rpms. At this low of a speed it looked like the pump was off. Also check the pumps communication ...I am assuming you have an Intelliflo. With the IntelliTouch in "Auto" the display should read "Display not active". ... The com bus is not working as the pump never says display not active. That is always my first check... Reply. Report. Jimrahbe. Mod Squad. ... Pentair MasterTemp not responding to ScreenLogic. Chas717; Jun 18, 2023; …Mar 1, 2020 · The computer drive for this Pentair Intelliflo VS pump Failed. The display shorted out, and no longer controllable. The how to steps for replacing the drive. Brand, Pentair. FinishColor, Almond. ForUseWith, IntelliFloXF, IntelliFlo 2 VST Pumps. Includes, Keypad Cover. Item, Keypad Assembly Kit ...San Diego. Jun 19, 2017. #5. Pressing the "Start/Stop" button with the pump running should stop the pump. If you then press the "Start/Stop" button again, that puts the pump in schedule mode. The word "Schedule" should appear on the screen, telling you it's ready to run the schedules that you've programmed into it.Pool Pump not Turning On? It could be okay. Trust me on this. Don't toss that pool pump motor until you try this simple trick to see if you can get it going ...The computer drive for this Pentair Intelliflo VS pump Failed. The display shorted out, and no longer controllable. The how to steps for replacing the drive.Apr 29, 2020 · About. Pentair Pool Quick Link for Parts/Equipment: https://amzn.to/3q6MXmf Ask your Questions or search from our database of answers: https://askthepoolguy.com/que... The IntelliFlo displays all alarms and warnings on the control panel display. When an alarm or warning condition. exists, the corresponding LED will be lit on the display. All control panel buttons are disabled until the alarm or. warning is acknowledged with the Enter button. Press the Reset button to clear the alarm once the fault.Jul 2, 2021 · Jul 2, 2021. #1. Similar threads found, but want to make sure I didn't miss an easier fix. My pump display went dead and the breaker was tripped. Reset the breaker and it energized the circuit. Can measure 240V across terminals (line1/2) at the timer box and at the pump (just inside as power comes in). I tried re-tripping breaker, holding down ... Jan 6, 2017 · The Pentair is feed through a a seimens 40 amp breaker. It looks like is 240v going to the pump. I'm new to all this so I sure I don't have it all correct. I followed the wires from the breaker to check for power on far left terminal and where the wire from the breaker is feed to the line in has power. The load out wire doesn't have power. Pentair intelliflo pool pump display only lasted 4 years and now the part is discontinued. ... Pentair - Display quit working after 4 years and is discontinued as ...A Pump That Knows Your Pool’s Flow. A pool that is crystal clear and inviting is key to the perfect backyard oasis. The IntelliFlo3 VSF Pool Pump leverages built-in sensorless flow control for optimum water flow adjusts to pool conditions, keeping your pool performing at its best. Set up, monitor and operate the pump from anywhere with ...Chlorine. Liquid Chlorine. Apr 3, 2022. #1. Quick Background: My old Aqualink RS4 cannot control the Pentair Intelliflow installed last year via RS-485 (unsupported). It's a simple single pump system so I have been running the on/off schedule via the Aqualink RS All Button (which basically controls the 240 volt power to the pump).Press the Start/Stop button on the drive keypad. If. the pump is currently scheduled to run it will start. Note: If the pump is not schedule to start, press a. Speed button to begin a manual override that will. start the pump. Check if the pump can be rotated by hand and. remove any blockage.The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. It is being practiced by thousands of pool owners just like you. We are a registered 501(c)3 non-profit that is funded by user donations. Please consider Supporting TFP!Our client called us stating the variable speed pool pump was not turning on and they are having to turning it on manually. Their home experienced a power ou...The SolarTouch Solar Control System offers full digital control for the most precise, efficient, swimming pool heating possible. The digital thermostat is set with the touch of a button and will monitor the temperature of the pool water and solar collectors. SolarTouch Control System integrates with IntelliFlo and IntelliPro Variable Speed pumps for …I just noticed that the LCD screen is blank. it does not show anything. the pump works fine however. I cannot program anything since i can't see what it is i am …Aug 11, 2015. #2. If the module failed, the most likely thing to go is the current protection thermistor. A fairly easy repair if you're handy with a soldering iron. If you're certain you have proper voltage at the pump connection, then I would check for smoked components on the controller. Of course, secure power first.A Pump That Knows A Pool's Flow A pool that is crystal clear and inviting is key to the perfect backyard oasis. The IntelliFlo3® VSF Pool Pump leverages built-in sensorless flow control for optimum water flow and adjusts to pool conditions, keeping pools performing at their best.The pump will continue to run, but it is not achieving the desired speed because it is running at the maximum flow rate. ... Ensure that the pump display says “ ...A Pump That Knows Your Pool’s Flow. A pool that is crystal clear and inviting is key to the perfect backyard oasis. The IntelliFlo3 VSF Pool Pump leverages built-in sensorless flow control for optimum water flow adjusts to pool conditions, keeping your pool performing at its best. Set up, monitor and operate the pump from anywhere with ...Ground and two hot leads.. The hot leads are called L1 and L2. Does not really matter which is which. Measure between L1 and L2 and not L1 to ground and then L2 to ground. What I would do is start with the pump off. Measure L1 to L2 and confirm that you have about 240 volts. If you do not have about 240 volts, there is no sense going any …If you have any questions please contact us through our website at: https://www.poolspecialists.com/Display issues can pop up in a few different ways: think flickering screens, touch controls that don't respond, or error messages that might look like gibberish if you're not familiar with them. When you encounter stuff like this, it's time to put on your detective hat and get troubleshooting.February 09, 2020. Communication issues are among the most common problems people run into with their Pentair pool equipment. The following problems can be caused by faulty communication: pressing a button on a remote or indoor controller does nothing. an Intelliflo pump won't run the schedule. screenlogic can't control the system.Jul 8, 2019 · I have had my Pentair intelliflo VS pump just over 2 years now. I just noticed that the LCD screen is blank. it does not show anything. the pump works fine however. I cannot program anything since i can't see what it is i am programming. i check out to replace the screen i need to... www.troublefreepool.com. Also, this youtube video that seem ... . Sunshine spa milford photos